• 27May
    2021
    G100

    In 2021, LS launched a new line of inverters – G100. The G100 is the solution for general drive applications because of its high performance Sensorless vector control premium quality and high reliability. G100 is designed to meet global standards through upgraded design, materials and manufacturing improving its endurance for harsh environments.

    Features

    1. Enhanced Reliability

    Built-in EMC Filter

    Reinforced Material Design

    MIL217PLUS based Design

    UL 61800-5-1 Design

    2. High Performance

    Application Adaptability

    Enhanced V/F Performance

    More Powerful Sensorless Control function

    3. User Convenience

    Built-in Potentiometer

    DIN rail Mountable (below 4kW)

    Output 2 Relays

    Quick Parameter Setting Group

    Various Communication Options

    Easy to connect to Peripherals (SMART Copier connection)

    Frame Design

    Type Designation

    Specification

    3-Phase 200V Class (0.4~22kW)
    G100-2 0004 0008 0015 0022 0040 0055 0075 0110 0150 0185 0220
    Motor Rating Heavy Duty(HD) (HP) 0.5 1.0 2.0 3.0 5 7.5 10 11 15 18.5 22
    (kW) 0.4 0.75 1.5 2.2 4.0 5.5 7.5 15 20 25 30
    Normal Duty (ND) (HP) 1.0 2.0 3.0 5 7.5 10 15 15 18.5 22
    (kW) 0.75 1.5 2.2 4.0 5.5 7.5 11 20 25 30
    Output Rating Capacity [kVA] Heavy Duty (HD) 1.0 1.9 3.0 4.2 6.5 9.1 12.2 17.9 22.9 28.6 33.5
    Normal Duty (ND) 1.2 2.3 3.8 4.6 6.9 11.4 15.2 21.3 26.7 31.2
    Rated Current
    (3-Phase Input) [A]
    Heavy Duty (HD) 2.5 5.0 8.5 11.0 17.0 24.0 32.0 47 60 75 88
    Normal Duty (ND) 3.1 6.0 9.6 12.0 18.0 30.0 40.0 56 70 82
    Rated Current
    (1-Phase Input) [A]
    Heavy Duty (HD) 1.5 2.8 4.6 6.1 9.3 12.8 17.4 26.8 34 41 48
    Normal Duty (ND) 2.0 3.6 5.9 6.7 9.8 16.3 22.0 31 38 45
    Frequency [Hz] 0~400Hz (IM sensorless: 0~120Hz)
    Voltage [V] 3-phase 200~240V
    Input Rating Voltage [V] 3-phase 200~240VAC (-15%~+10%)
    Frequency [Hz] 50~60Hz (±5%)
    Rated Current [A] Heavy Duty (HD) 2.2 4.9 8.4 11.8 18.5 25.8 34.9 53.2 68.4 85.5 101.6
    Normal Duty (ND) 3.0 6.3 10.8 13.1 19.4 32.7 44.2 63.8 79.8 94.6
    Weight [kg] 1.04 1.06 1.36 1.4 1.89 3.08 3.21 4.84 7.6 11.1 11.18
    3-Phase 400V Class (0.4~22kW)
    G100-4 0004 0008 0015 0022 0040 0055 0075 0110 0150 0185 0220
    Motor Rating Heavy Duty (HD) (HP) 0.5 1.0 2.0 3.0 5 7.5 10 11 15 18.5 22
    (kW) 0.4 0.75 1.5 2.2 4.0 5.5 7.5 15 20 25 30
    Normal Duty (ND) (HP) 1.0 2.0 3.0 5 7.5 10 15 15 18.5 22 30
    (kW) 0.75 1.5 2.2 4.0 5.5 7.5 11 20 25 30 40
    Output Rating Capacity [kVA] Heavy Duty (HD) 1.0 1.9 3.0 4.2 6.5 9.1 12.2 18.3 23.6 29.7 34.3
    Normal Duty (ND) 1.5 2.4 3.9 5.3 7.6 12.2 17.5 23.6 29.0 34.3 46.5
    Rated Current
    (3-Phase Input) [A]
    Heavy Duty (HD) 1.3 2.5 4.0 5.5 9.0 12.0 16.0 24 31 39 45
    Normal Duty (ND) 2.0 3.1 5.1 6.9 10.0 16.0 23.0 31 38 45 61
    Rated Current
    (1-Phase Input) [A]
    Heavy Duty (HD) 0.7 1.4 2.1 2.8 4.9 6.4 8.7 15 18 23 27
    Normal Duty (ND) 1.3 1.9 2.8 3.6 5.4 8.7 12.6 18 23 27 35
    Frequency [Hz] 0~400Hz (IM sensorless: 0~120Hz)
    Voltage [V] 3-phase 380~480V
    Input Rating Voltage [V] 3-phase 380~480VAC (-15%~+10%)
    Frequency [Hz] 50~60Hz (±5%)
    Rated Current [A] Heavy Duty (HD) 1.1 2.4 4.2 5.9 9.8 12.9 17.5 27.2 35.3 44.5 51.9
    Normal Duty (ND) 2.0 3.3 5.5 7.5 10.8 17.5 25.4 35.3 43.3 51.9 70.8
    Weight [kg] 1.02 (1.04) 1.06 (1.08) 1.4 (1.44) 1.42 (1.46) 1.92 (1.98) 3.08 (3.24) 3.12 (3.28) 4.89 (5.04) 4.91 (5.06) 7.63 (7.96) 7.65 (7.98)
    Control
    Control Method V/F, Slip Compensation, Sensorless Vector Frequency Setting
    Frequency Setting Resolution Digital command: 0.01Hz
    Analog command: 0.06Hz(maximum frequency: 60 Hz)
    Frequency Accuracy 1% of the maximum output frequency
    V/F Pattern Linear, squared, user V/F
    Overload Capacity HD: 150% 1 minute, ND: 120% 1minute
    Torque Boost Manual/Automatic torque boost
    Operation
    Operation Mode Select key pad, terminal strip, or communication operation
    Frequency Setting Analog: -10~10[V], 0~10[V], 4~20[mA]
    Digital: Keypad
    Operation Function PID control, 3-wire operation, Frequency limit, Second function, Anti-forward and reverse direction rotation,
    Commercial transition, Speed search, Power braking, Leakage reduction, Up-down operation, DC braking,
    Frequency jump, Slip compensation, Automatic restart, Automatic tuning,
    Energy buffering, Flux braking, Fire mode
    Input Multi-Function Terminal
    (5 Points)
    NPN (Sink) / PNP (Source) Selectable
    Function: Forward run, Reverse run, Reset, External trip, Emergency stop, Jog operation,
    Multi-step frequency-high, middle, low, Multi-step acceleration/ deceleration-high, middle, low,
    DC braking at stop, 2nd motor select, Frequency up/down, 3-wire operation,
    Change into normal operation during PID operation Change into main operation during option operation,
    Analog command frequency fixing, Acceleration/deceleration stop etc. Selectable
    Analog Input V1: -10~10V, I2 4~20mA
    Output Multi-function Relay Terminal Fault output and drive operation status output (N.O., N.C.) less than AC 250V 1A, less than DC 30V 1A
    Analog Output 0~12Vdc: Frequency, Output current, Output voltage, DC stage voltage etc. selectable
    Protective Function
    Trip Over current trip, external signal trip, ARM short
    current fault trip, over heat trip, input imaging trip,
    ground trip, motor over heat trip,
    I/O board trip, no motor trip, parameter writing trip,
    emergency stop trip, command loss trip,
    external memory error, CPU watchdog trip,
    motor light load trip
    Over voltage trip, temperature sensor trip,
    inverter over heat, option trip,
    output image trip, inverter overload trip,
    fan trip, pre-PID operation
    failure external brake trip,
    low voltage trip during operation, low voltage trip,
    analog input error, motor overload trip,
    over torque trip, under torque trip
    Alarm Command loss trip warning, overload warning, light load warning, inverter overload warning,
    fan operation warning, braking resistance braking rate warning, rotor time constant tuning error,
    inverter pre-overheat warning, over torque warning, under torque warning
    Momentary Power Loss HD below 15ms (ND below 8ms): Continuous operation (To be within rated input voltage,
    rated output) HD above 15ms (ND above 8ms): Automatic restart operation enable
    Environment
    Cooling Type Forced fan cooling structure
    Protection Degree IP20/UL Open (Default), UL Enclosed type 1 (Option)
    Ambient Temperature Ambient temperature under the condition of no ice or frost.
    HD: -10~50℃(14~122°F) / ND: -10~40℃(14~104°F)
    [However, recommended to use load below 80% when using at 50°C under light load]
    Humidity Relative humidity below 95% RH (no dew formation)
    Storage Temperature -20~65℃(-4~149°F)
    Location No corrosive gas, flammable gas, oil mist and dust etc. indoors (Pollution degree 2 environment)
    Altitude, Vibration Below 1,000m (From 1000 to 4000m, the rated input voltage and rated output current
    of the drive must be derated by 1% for every 100m.), below 9.8m/sec2 (1G)
    Pressure 70~106kPa